BidPreflight · Public Example (Scotland, UK (Multi-Sheet Bill of Quantities)) · Operated by PreflightBench · Free Preview / $39 one-time full unlock
← All Examples Audit Your Own Bid Package Free →

Bid Addendum Preflight Report — Aberdeen JUL560028 (UK) — 21-Sheet Protected BoQ Rev A Audit

Authoritative Latest Schedule: Vol2_Appendix4_BoQ_RevA.xlsx · Full Deterministic Audit
Sample Data Notice: Owner-only revision diff generated directly from official Aberdeen City Council public tender files (no contractor pricing supplied).
Hard Blockers
0
Warnings
7
Quantified Risk
£0.00
Rows Audited
186
Safe Cells Written
0

Findings & Hard-Gate Checks

WARNING RATE_ONLY_SPEC_CHANGED B500_Drainage!E28

Rate-Only item #12 specification changed (reference depth 1.2m → 1.0m)

B500_Drainage!Row 28: description updated from 'Adjustment on last item for variation greater than 150mm above or belo' to 'Adjustment on last item for variation greater than 150mm above or belo'.

Action: Review and confirm Rate Only pricing under updated specification.

WARNING RATE_ONLY_SPEC_CHANGED B500_Drainage!E40

Rate-Only item #14 specification changed (reference depth 0.85m → 0.45m)

B500_Drainage!Row 40: description updated from 'Adjustment on last item for variation greater than 150mm above or belo' to 'Adjustment on last item for variation greater than 150mm above or belo'.

Action: Review and confirm Rate Only pricing under updated specification.

WARNING RATE_ONLY_SPEC_CHANGED B500_Drainage!E44

Rate-Only item #16 specification changed (reference depth 0.45m → 0.85m)

B500_Drainage!Row 44: description updated from 'Adjustment on last item for variation greater than 150mm above or belo' to 'Adjustment on last item for variation greater than 150mm above or belo'.

Action: Review and confirm Rate Only pricing under updated specification.

WARNING SPLIT_ITEM_REVIEW B700_Pavements!E20

Item #7 (Hot rolled asphalt 30/14F surf 40/60 Des PSV ) is part of a split specification item

Original item #7 was split into #7, #7A at B700_Pavements!Row 20 (1349 m2). Confirm distinct rate for each grade.

Action: Confirm independent unit rate for each split item grade.

WARNING SPLIT_ITEM_REVIEW B700_Pavements!E22

Item #7A (Hot rolled asphalt 30/14F surf 40/60 Des PSV ) is part of a split specification item

Original item #7 was split into #7, #7A at B700_Pavements!Row 22 (2164 m2). Confirm distinct rate for each grade.

Action: Confirm independent unit rate for each split item grade.

WARNING SUMMARY_DISCOUNT_WITHDRAWN Summary!R22

Summary discount/incentive row removed at Summary!Row 22

Prior workbook had 'Discount offered through Aberdeen City Council Supplier Incentive Scheme | %' (editable=True); removed in latest revision.

Action: Do not include withdrawn discount/incentive form or adjustment in final bid.

WARNING NO_SUBTOTAL_FORMULAS Vol2_Appendix4_BoQ_RevA.xlsx

Schedule has no Excel formulas on subtotal/total rows

All subtotal/total cells are static values or blank; verify manual arithmetic against independent Decimal totals.

Action: Cross-check every manually entered subtotal against the Audit Totals table.

Independent Decimal Group Totals

SheetGroupActive ItemsPricedIndependent TotalReported TotalStatus
A100_Prelims A100_Prelims 2 0 / 2 £0.00 — INCOMPLETE
B200_SiteClearance B200_SiteClearance 21 0 / 21 £0.00 — INCOMPLETE
B300_Fencing B300_Fencing 8 0 / 8 £0.00 — INCOMPLETE
B500_Drainage B500_Drainage 27 0 / 27 £0.00 — INCOMPLETE
B600_Earthworks B600_Earthworks 27 0 / 27 £0.00 — INCOMPLETE
B700_Pavements B700_Pavements 11 0 / 11 £0.00 — INCOMPLETE
B1100_Kerbs-Footways B1100_Kerbs-Footways 4 0 / 4 £0.00 — INCOMPLETE
B1200_TrafficSigns-RoadMarkings B1200_TrafficSigns-RoadMarkings 22 0 / 22 £0.00 — INCOMPLETE
B1400_Electrical B1400_Electrical 6 0 / 6 £0.00 — INCOMPLETE
B2700_AccommWorks B2700_AccommWorks 4 0 / 4 £0.00 — INCOMPLETE
B3000_Landscape B3000_Landscape 12 0 / 12 £0.00 — INCOMPLETE
C200_SiteClearance C200_SiteClearance 2 0 / 2 £0.00 — INCOMPLETE
C600_Earthworks C600_Earthworks 14 0 / 14 £0.00 — INCOMPLETE
C1700_StrucConcrete C1700_StrucConcrete 7 0 / 7 £0.00 — INCOMPLETE
C2400_Blockwork C2400_Blockwork 1 0 / 1 £0.00 — INCOMPLETE
C2500_SpecialStructures C2500_SpecialStructures 4 0 / 4 £0.00 — INCOMPLETE

Complete Line-by-Line Audit (186 total rows · 16 flagged / changed)

CellGroupItem#Description Latest Qty/UnitPrior Qty/Unit Contractor RateStatusAudit Note
A100_Prelims!R26 A100_Prelims 10 Survey Engineer for the Overseeing Organisation 20 op.day 20 op.day — EXACT_SAFE Matched cleanly.
A100_Prelims!R30 A100_Prelims 11 Information board as detailed in Appendix 1/21 3 no 3 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R6 B200_SiteClearance 1 General Site Clearance Area 1 0.262 Ha 0.262 Ha — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R8 B200_SiteClearance 2 General Site Clearance Area 2 0.984 Ha 0.984 Ha — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R10 B200_SiteClearance 3 General Site Clearance Area 3 0.263 Ha 0.263 Ha — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R14 B200_SiteClearance 4 Take up or down and remove to tip off site stonework (in walls) 627 m3 627 m3 — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R16 B200_SiteClearance 5 Take up or down and remove to tip off site post and barbed wire fencing 356 m 356 m — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R18 B200_SiteClearance 6 Take up or down and remove to tip off site wooden fencing 8 m 8 m — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R20 B200_SiteClearance 7 Take up or down and remove to tip off site traffic sign post 5 no 5 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R22 B200_SiteClearance 8 Take up or down and remove to tip off site traffic lit sign post 5 no 5 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R24 B200_SiteClearance 9 Take up or down and remove to tip off site half post and chevron marker 8 no 8 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R26 B200_SiteClearance 10 Take up or down and set aside for reuse traffic sign face not exceeding 0.50 square metres (Direction Sign) 1 no 1 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R28 B200_SiteClearance 11 Take up or down and set aside for reuse traffic sign and supplementary plate sign face not exceeding 0.50 squa 2 no 2 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R30 B200_SiteClearance 12 Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( 5 no 5 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R32 B200_SiteClearance 13 Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( 2 no 2 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R34 B200_SiteClearance 14 Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( 2 no 2 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R36 B200_SiteClearance 15 Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( 2 no 2 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R38 B200_SiteClearance 16 Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( 2 no 2 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R40 B200_SiteClearance 17 Take up or down and set aside for reuse traffic sign face not exceeding 0.50 square metres (Give Way Sign) 1 no 1 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R49 B200_SiteClearance 18 Take up or down and remove to tip off site bollard 4 no 4 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R51 B200_SiteClearance 19 Take up or down and remove to tip off site gully grating and frame 6 no 6 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R53 B200_SiteClearance 20 Take up or down and set aside for reuse steel farm gates 2 no 2 no — EXACT_SAFE Matched cleanly.
B200_SiteClearance!R55 B200_SiteClearance 21 Take up or down and set aside for reuse timber posts for the farm gates 2 no 2 no — EXACT_SAFE Matched cleanly.
B300_Fencing!R6 B300_Fencing 1 Wooden post and 6 wire (barbed) fence 1.15m high as per ACC Standard Detail H77 237 m 237 m — EXACT_SAFE Matched cleanly.
B300_Fencing!R8 B300_Fencing 2 Straining posts as per Standard Detail H7 4 no 4 no — EXACT_SAFE Matched cleanly.
B300_Fencing!R10 B300_Fencing 3 Concrete foundation to straining posts 4 no 4 no — EXACT_SAFE Matched cleanly.
B300_Fencing!R14 B300_Fencing 4 Remove from store and re-erect steel field gate 5m wide x 1m high 2 no 2 no — EXACT_SAFE Matched cleanly.
B300_Fencing!R16 B300_Fencing 5 Remove from store and re-erect timber posts 1.8m in length 2 no 2 no — EXACT_SAFE Matched cleanly.
B300_Fencing!R18 B300_Fencing 6 Concrete foundation to timber posts for farm gate 2 no 2 no — EXACT_SAFE Matched cleanly.
B300_Fencing!R22 B300_Fencing 7 Excavation in Hard Material 1 m3 1 m3 — EXACT_SAFE Matched cleanly.
B300_Fencing!R26 B300_Fencing 8 Handrail for Headwall Detail HW01 1 no 1 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R6 B500_Drainage 1 150mm internal diameter drain specified design Group 1 inside slopes of cuttings or side slopes of embankments 53 m 53 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R8 B500_Drainage 2 Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R10 B500_Drainage 3 150mm internal diameter drain specified design Group 5 in trench depth to invert not exceeding 2 metres, avera 51 m 51 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R12 B500_Drainage 4 Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R14 B500_Drainage 5 225mm internal diameter drain specified design Group 5 in trench depth to invert not exceeding 2 metres, avera 37 m 37 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R16 B500_Drainage 6 Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R18 B500_Drainage 7 300mm internal diameter drain specified design Group 1 in trench depth to invert not exceeding 2 metres, avera 8 m 8 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R20 B500_Drainage 8 Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R22 B500_Drainage 9 300mm internal diameter drain specified design Group 5 in trench depth to invert not exceeding 2 metres, avera 14 m 14 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R24 B500_Drainage 10 Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R26 B500_Drainage 11 150mm internal diameter drain on bed Type Z in trench depth to invert not exceeding 2 metres, average depth to 9 m 9 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R28 B500_Drainage 12 Adjustment on last item for variation greater than 150mm above or below average depth of 1.0 metres per 25mm o m m — RATE_ONLY_REVIEW Rate-Only specification changed (reference depth 1.2m → 1.0m).
B500_Drainage!R38 B500_Drainage 13 One number 100mm internal diameter corrugated purple uPVC with smooth inner surface service duct on bed Type T 375 m 375 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R40 B500_Drainage 14 Adjustment on last item for variation greater than 150mm above or below the average depth of 0.45 metres per 2 m m — RATE_ONLY_REVIEW Rate-Only specification changed (reference depth 0.85m → 0.45m).
B500_Drainage!R42 B500_Drainage 15 Two number 100mm internal diameter corrugated purple uPVC with smooth inner surface service duct on bed Type T 44 m 44 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R44 B500_Drainage 16 Adjustment on last item for variation greater than 150mm above or below the average depth of 0.85 metres per 2 m m — RATE_ONLY_REVIEW Rate-Only specification changed (reference depth 0.45m → 0.85m).
B500_Drainage!R48 B500_Drainage 17 One number 100mm internal diameter black uPVC service duct on bed Type T in trench depth to invert not exceedi 22 m 22 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R50 B500_Drainage 18 Adjustment on last item for variation greater than 150mm above or below the average depth of 0.75 metres per 2 m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R52 B500_Drainage 19 One number 100mm internal diameter black uPVC service duct on bed Type T in trench depth to invert not exceedi 130 m 130 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R54 B500_Drainage 20 Adjustment on last item for variation greater than 150mm above or below the average depth of 0.55 metres per 2 m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R58 B500_Drainage 21 Drain or Service Protection 12 m 12 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R62 B500_Drainage 22 150mm internal diameter filter drain in trench specified design Group 2 depth to invert not exceeding 2 metres 411 m 411 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R72 B500_Drainage 23 Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o m m — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B500_Drainage!R74 B500_Drainage 24 Type B filter material contiguous with filter drain 73 m3 73 m3 — EXACT_SAFE Matched cleanly.
B500_Drainage!R78 B500_Drainage 25 Narrow filter drain Type 9 depth not exceeding 1.5 metres 37 m 37 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R82 B500_Drainage 26 Connection of 150mm diameter pipe to existing 150mm diameter drain or existing piped culvert depth to invert n 2 no 2 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R86 B500_Drainage 27 Trapped gully specified design group Type G1 with D400 grating and frame 7 no 7 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R88 B500_Drainage 28 Precast concrete chamber Type 7 (1050) Catchpit with D400 cover and frame depth to invert exceeding 1 metres b 15 no 15 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R90 B500_Drainage 29 Sectional uPVC footway chamber 450 x 450mm for Street Lighting with cover and frame, depth to uppermost surfac 6 no 6 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R92 B500_Drainage 30 150mm diameter rodding eye (as per SD F84) 5 no 5 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R96 B500_Drainage 31 Headwall (precast concrete) type HW01, pipe exceeding 100mm but not exceeding 300mm internal diameter as per D 1 no 1 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R100 B500_Drainage 32 Excavation of soft spots and other voids in the bottom of trenches, chambers and gullies 5 m3 5 m3 — EXACT_SAFE Matched cleanly.
B500_Drainage!R102 B500_Drainage 33 Filling of soft spots and other voids in the bottom of trenches, chambers and gullies 5 m3 5 m3 — EXACT_SAFE Matched cleanly.
B500_Drainage!R106 B500_Drainage 34 Extra over excavation for excavation in Hard Material in drainage 20 m3 20 m3 — EXACT_SAFE Matched cleanly.
B500_Drainage!R108 B500_Drainage 35 Cleaning filter drainage system from CP01 220 m 220 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R110 B500_Drainage 36 Cleaning piped drainage system at connection of Catch Pit CP12 to outfall at Burn of Mundurno 10 m 10 m — EXACT_SAFE Matched cleanly.
B500_Drainage!R120 B500_Drainage 37 Cleaning of gullies on existing piped drainage system 4 no 4 no — EXACT_SAFE Matched cleanly.
B500_Drainage!R124 B500_Drainage 38 Infiltration trench 150 dia drain depth to invert not exceeding 2 metres 36 m 36 m — EXACT_SAFE Matched cleanly.
B600_Earthworks!R6 B600_Earthworks 1 Excavation of acceptable material Class 5A (topsoil) 2347 m3 2347 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R8 B600_Earthworks 2 Excavation of acceptable material excluding Class 5A in cutting and other excavation 809 m3 809 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R10 B600_Earthworks 3 Excavation of acceptable material excluding Class 5A in intercepting ditches 400 m3 400 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R12 B600_Earthworks 4 Excavation of unacceptable material Class U1A in cutting or other excavation 3299 m3 3299 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R16 B600_Earthworks 5 Extra over excavation for excavation in Hard Material in cutting or other excavation 583 m3 583 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R18 B600_Earthworks 6 Extra over excavation for excavation in Hard Material in intercepting ditches 5 m3 5 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R20 B600_Earthworks 7 Processing of unacceptable material Class U1A into acceptable material (PROVISIONAL) m3 m3 — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B600_Earthworks!R24 B600_Earthworks 8 Deposition of acceptable material in embankments and other areas of fill 1209 m3 1209 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R26 B600_Earthworks 9 Deposition of acceptable material in fill on sub-base material, base and capping 14 m3 14 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R30 B600_Earthworks 10 Disposal of unacceptable material Class U1A 3299 m3 3299 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R32 B600_Earthworks 11 Disposal of acceptable material Class 5A 1000 m3 1000 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R36 B600_Earthworks 12 Imported acceptable material in embankments and other area of fill 7781 m3 7781 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R38 B600_Earthworks 13 Imported acceptable material in embankments and other areas of fill (intercepting ditches) as per Drawing No C 26 m3 26 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R42 B600_Earthworks 14 Compaction of acceptable material in embankments and other areas of fill 8990 m3 8990 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R44 B600_Earthworks 15 Compaction of acceptable material in fill on sub-base material, base and capping 14 m3 14 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R48 B600_Earthworks 16 Geotextile in carriageway (PROVISIONAL) 3956 m2 3956 m2 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R52 B600_Earthworks 17 Excavation of soft spots and other voids below cuttings or under embankments 20 m3 20 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R54 B600_Earthworks 18 Filling of soft spots and other voids below cuttings or under embankments with acceptable material 20 m3 20 m3 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R64 B600_Earthworks 19 Removal of disused gully internal diameter 0.5m 4 no 4 no — EXACT_SAFE Matched cleanly.
B600_Earthworks!R68 B600_Earthworks 20 Topsoiling 150mm thick to surfaces sloping at 10 degrees or less to the horizontal 5728 m2 5728 m2 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R70 B600_Earthworks 21 Topsoiling 150mm thick to surfaces sloping more than 10 degrees to the horizontal 2395 m2 2395 m2 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R72 B600_Earthworks 22 Topsoiling 250mm thick to surfaces sloping at 10 degrees or less to the horizontal 120 m2 120 m2 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R74 B600_Earthworks 23 Topsoiling 250mm thick to surfaces sloping more than 10 degrees to the horizontal 472 m2 472 m2 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R78 B600_Earthworks 24 Completion of formation on acceptable material 3956 m2 3956 m2 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R82 B600_Earthworks 25 Lining of new intercepting ditches to side slopes 770 m2 770 m2 — EXACT_SAFE Matched cleanly.
B600_Earthworks!R86 B600_Earthworks 26 Clearing of existing Burn of Mundurno at existing culvert 45 m 45 m — EXACT_SAFE Matched cleanly.
B600_Earthworks!R90 B600_Earthworks 27 Removal of standpipes, depth not exceeding 10 metres 3 no 3 no — EXACT_SAFE Matched cleanly.
B600_Earthworks!R94 B600_Earthworks 28 Trial pit 0-3 metres in depth 20 m3 20 m3 — EXACT_SAFE Matched cleanly.
B700_Pavements!R6 B700_Pavements 1 Type 1 unbound mixture sub-base in carriageway, hardshoulder and hardstrip 1028 m3 1028 m3 — EXACT_SAFE Matched cleanly.
B700_Pavements!R10 B700_Pavements 2 AC32 dense base 40/60 Des, 175mm thick in carriageway, hardshoulder and hardstrip 3494 m2 3494 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R12 B700_Pavements 3 AC20 dense binder course 40/60 Des, 60mm thick in carriageway, hardshoulder and hardstrip 3430 m2 3430 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R14 B700_Pavements 4 AC20 dense binder course 40/60 Des, 75mm thick in carriageway, hardshoulder and hardstrip 45 m2 45 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R16 B700_Pavements 5 AC20 dense binder course 40/60 Des, 90mm thick in carriageway, hardshoulder and hardstrip 198 m2 198 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R18 B700_Pavements 6 Hot rolled asphalt 30/14F surf 40/60 Des, with 14mm aggregate surface course 30mm thick with 14/20mm coated ch 187 m2 187 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R20 B700_Pavements 7 Hot rolled asphalt 30/14F surf 40/60 Des PSV 60, with 14mm aggregate surface course 45mm thick with 14/20mm co 1349 m2 3450 m2 — SPLIT_OR_AMBIGUOUS Split from prior single item; requires rate confirmation.
B700_Pavements!R22 B700_Pavements 7A Hot rolled asphalt 30/14F surf 40/60 Des PSV 65, with 14mm aggregate surface course 45mm thick with 14/20mm co 2164 m2 — SPLIT_OR_AMBIGUOUS Split from prior single item; requires rate confirmation.
B700_Pavements!R26 B700_Pavements 8 Regulating binder course AC20 dense bin 40/60 Des in carriageway, hardshoulder and hardstrip to Clause 907 (PR m3 m3 — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B700_Pavements!R30 B700_Pavements 9 Tack Coat 7256 m2 7256 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R34 B700_Pavements 10 Milling pavement not exceeding 60mm deep 38 m2 38 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R36 B700_Pavements 11 Milling pavement exceeding 60mm deep but not exceeding 120mm deep 15 m2 15 m2 — EXACT_SAFE Matched cleanly.
B700_Pavements!R40 B700_Pavements 12 Reinstate paved areas with permanent reinstatement as detailed in Appendix 7/2, paragraph 5 of the Specificati m2 m2 — RATE_ONLY_REVIEW Rate-Only item (excluded from extended quantity sum).
B1100_Kerbs-Footways!R6 B1100_Kerbs-Footways 1 Precast concrete kerb Type K2 laid straight or curved exceeding 12 metres radius 129 m 129 m — EXACT_SAFE Matched cleanly.
B1100_Kerbs-Footways!R8 B1100_Kerbs-Footways 2 Precast concrete kerb Type K2 laid to curves not exceeding 12 metres radius 25 m 25 m — EXACT_SAFE Matched cleanly.
B1100_Kerbs-Footways!R10 B1100_Kerbs-Footways 3 Precast concrete kerb Type K6 laid straight or curved exceeding 12 metres radius 1 m 1 m — EXACT_SAFE Matched cleanly.
B1100_Kerbs-Footways!R12 B1100_Kerbs-Footways 4 Precast concrete kerb Type K7 laid straight or curved exceeding 12 metres radius 1 m 1 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R6 B1200_TrafficSigns-RoadMarkings 1 Permanent retroreflective traffic sign to Diagram 670 (40mph) as Lit Sign Unit sign face exceeding 0.25 square 2 no 2 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R8 B1200_TrafficSigns-RoadMarkings 2 Temporary retroreflective traffic sign to Diagram 7014 (New Road Layout Ahead) as non-Lit Sign Unit sign face 1 no 1 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R10 B1200_TrafficSigns-RoadMarkings 3 Temporary retroreflective traffic sign to Diagram 7014 (New Road Layout Ahead) as non-Lit Sign Unit sign face 2 no 2 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R12 B1200_TrafficSigns-RoadMarkings 4 Remove from store and re-erect retroreflective traffic sign to Diagram 671 (National Speed Limit @750mm Ø) as 2 no 2 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R14 B1200_TrafficSigns-RoadMarkings 5 Remove from store and re-erect retroreflective traffic sign to Diagram 670 (40mph @750mm Ø) as lit Sign Unit s 2 no 2 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R16 B1200_TrafficSigns-RoadMarkings 6 Remove from store and re-erect retroreflective traffic signs back to back to Diagram 670 (40mph & 30mph @600mm 2 no 2 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R18 B1200_TrafficSigns-RoadMarkings 7 Remove from store and re-erect retroreflective traffic signs to Diagram 512.1 and supplementary plate to Diag 2 no 2 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R20 B1200_TrafficSigns-RoadMarkings 8 Remove from store and re-erect retroreflective traffic sign to Diagram 602 (Give way) as non lit Sign Unit sig 1 no 1 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R22 B1200_TrafficSigns-RoadMarkings 9 Remove from store and re-erect retroreflective traffic sign x 2no back to back (Direction Sign) as non lit Sig 1 no 1 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R32 B1200_TrafficSigns-RoadMarkings 10 Remove from store and re-erect retroreflective traffic signs back to back to Diagram 670 & Diagram 671 (40mph 2 no 2 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R36 B1200_TrafficSigns-RoadMarkings 11 Continuous line in white thermoplastic screed with applied solid glass beads 0.150 metres wide (Diag 1012.1 Ha 791 m 791 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R38 B1200_TrafficSigns-RoadMarkings 12 Intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with 4 metre li 262 m 262 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R40 B1200_TrafficSigns-RoadMarkings 13 Intermittent line in white thermoplastic screed with applied solid glass beads 0.2 metres wide with 0.6 metre 18 m 18 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R42 B1200_TrafficSigns-RoadMarkings 14 Intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with 0.6 metre 7 m 7 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R44 B1200_TrafficSigns-RoadMarkings 15 Intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with 1 metre li 39 m 39 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R46 B1200_TrafficSigns-RoadMarkings 16 Ancillary line in white thermoplastic screed with applied solid glass beads 0.15 metres wide in hatched areas 5 m 5 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R48 B1200_TrafficSigns-RoadMarkings 17 Triangle in white thermoplastic screed with applied solid glass beads to (Diag 1023A) 1 no 1 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R50 B1200_TrafficSigns-RoadMarkings 18 Letters in white thermoplastic screed with applied solid glass beads 1.6 metres high (Diag 1024 Slow) 16 no 16 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R52 B1200_TrafficSigns-RoadMarkings 19 Removal of continuous line in white thermoplastic screed with applied solid glass beads 0.150 metres wide (Dia 10 m 10 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R54 B1200_TrafficSigns-RoadMarkings 20 Removal of intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with 12 m 12 m — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R64 B1200_TrafficSigns-RoadMarkings 21 Removal of letters in white thermoplastic screed with applied solid glass beads 1.6 metres high (Diag 1024 Slo 4 no 4 no — EXACT_SAFE Matched cleanly.
B1200_TrafficSigns-RoadMarkings!R68 B1200_TrafficSigns-RoadMarkings 22 Permanent bollard retro-reflective, Weebol style with blank aspect within NAL 50 x 50mm retention socket 1 no 1 no — EXACT_SAFE Matched cleanly.
B1400_Electrical!R7 B1400_Electrical 1 2.5mm2 3 Core XLPE/SWA/PVC cable with copper conductors 148 m 148 m — EXACT_SAFE Matched cleanly.
B1400_Electrical!R13 B1400_Electrical 3 Single way cut out termination to 3 core PVC/SWA/PVC cable in road lighting column or feeder pillar 12 no 12 no — EXACT_SAFE Matched cleanly.
B1400_Electrical!R15 B1400_Electrical 4 Two way cut out termination to 3 core PVC/SWA/PVC cable in road lighting column 1 no 1 no — EXACT_SAFE Matched cleanly.
B1400_Electrical!R17 B1400_Electrical 5 Supply and install cut out unit in sign lighting column 7 no 7 no — EXACT_SAFE Matched cleanly.
B1400_Electrical!R19 B1400_Electrical 6 Supply and install cut out unit in lighting column no. 44 Denmore Road 1 no 1 no — EXACT_SAFE Matched cleanly.
B1400_Electrical!R23 B1400_Electrical 7 Supply and install earth pit and rod sign pole 3 no 3 no — EXACT_SAFE Matched cleanly.
B2700_AccommWorks!R7 B2700_AccommWorks 1 Trench for Openreach BT duct exceeding 300 mm but not exceeding 450 mm wide depth not exceeding 1.5m in carria 6 m 6 m — EXACT_SAFE Matched cleanly.
B2700_AccommWorks!R9 B2700_AccommWorks 2 Trench for Openreach BT duct exceeding 300 mm but not exceeding 450 mm wide depth not exceeding 1.5m in verges 295 m 295 m — EXACT_SAFE Matched cleanly.
B2700_AccommWorks!R13 B2700_AccommWorks 3 Excavation of Joint hole depth not exceeding 1.5m in verges to locate SSE Distribution cables 2 no 2 no — EXACT_SAFE Matched cleanly.
B2700_AccommWorks!R15 B2700_AccommWorks 4 Excavation of Joint hole depth not exceeding 1.5m in carriageways, footways and paved areas to locate SSE Dist 2 no 2 no — EXACT_SAFE Matched cleanly.
B3000_Landscape!R6 B3000_Landscape 1 Vegetation clearance to surfaces sloping at 10 degrees or less to the horizontal 5848 m2 5848 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R8 B3000_Landscape 2 Vegetation clearance to surfaces sloping at more than 10 degrees to the horizontal 2867 m2 2867 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R10 B3000_Landscape 3 Final preparation of surfaces sloping at 10 degrees or less to the horizontal 5848 m2 5848 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R12 B3000_Landscape 4 Final preparation of surfaces sloping at more than 10 degrees to the horizontal 2867 m2 2867 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R14 B3000_Landscape 5 Final cultivations to surfaces sloping at 10 degrees or less to the horizontal 5848 m2 5848 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R16 B3000_Landscape 6 Final cultivations to surfaces sloping at more than 10 degrees to the horizontal 2867 m2 2867 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R20 B3000_Landscape 7 Grass seeding to Amenity Grassland areas at 35g/sqm by conventional sowing to surfaces sloping at 10 degrees o 2680 m2 2680 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R22 B3000_Landscape 8 Grass seeding to Amenity Grassland area at 35g/sqm by conventional sowing areas to surfaces sloping at more th 734 m2 734 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R24 B3000_Landscape 9 Grass seeding to Species Rich Grassland at 3g/sqm by conventional sowing to surfaces sloping at 10 degrees or 114 m2 114 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R26 B3000_Landscape 10 Grass seeding to Species Rich Grassland at 3g/sqm by conventional sowing to surfaces sloping at more than 10 d 452 m2 452 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R28 B3000_Landscape 11 Grass seeding to Meadow Mix at 3g/sqm by conventional sowing to surfaces sloping at 10 degrees or less to the 2830 m2 2830 m2 — EXACT_SAFE Matched cleanly.
B3000_Landscape!R30 B3000_Landscape 12 Grass seeding to Meadow Mix at 3g/sqm by conventional sowing to surfaces sloping at more than 10 degrees to th 1582 m2 1582 m2 — EXACT_SAFE Matched cleanly.
C200_SiteClearance!R6 C200_SiteClearance 1 Partial demolition of of existing culvert - 750mm diameter precast concrete pipe 5 m 5 m — EXACT_SAFE Matched cleanly.
C200_SiteClearance!R8 C200_SiteClearance 2 Partial demolition of existing culvert - stone culvert comprising random rubble wall, granite roof slabs and c 4 m 4 m — EXACT_SAFE Matched cleanly.
C600_Earthworks!R6 C600_Earthworks 1 Excavation of acceptable material Class 5A (topsoil) in culvert 40 m3 40 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R8 C600_Earthworks 2 Excavation of acceptable material excluding Class 5A in culvert 60 m3 60 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R10 C600_Earthworks 3 Excavation of unacceptable material Class U1A in culvert 60 m3 60 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R14 C600_Earthworks 4 Extra over excavation for excavation in Hard Material in culvert 3 m3 3 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R18 C600_Earthworks 5 Deposition of acceptable material in embankments and other areas of fill 40 m3 40 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R20 C600_Earthworks 6 Deposition of acceptable material Class 5A in embankments and other areas of fill 20 m3 20 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R23 C600_Earthworks 7 Disposal of unacceptable material Class U1A 60 m3 60 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R27 C600_Earthworks 8 Imported acceptable material Class 1A in base of culvert 8 m3 8 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R29 C600_Earthworks 9 Imported acceptable well graded course granular material suitable for use in a watercourse as bedding in culve 5 m3 5 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R33 C600_Earthworks 10 Compaction of acceptable material Class 1A in base of culvert 8 m3 8 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R35 C600_Earthworks 11 Compaction of acceptable material in embankments and other areas of fill 60 m3 60 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R39 C600_Earthworks 12 Geotextile membrane in culvert 24 m2 24 m2 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R43 C600_Earthworks 13 Excavation of soft spots and other voids below cuttings or under embankments 2 m3 2 m3 — EXACT_SAFE Matched cleanly.
C600_Earthworks!R45 C600_Earthworks 14 Filling of soft spots and other voids below cuttings or under embankments with acceptable material 2 m3 2 m3 — EXACT_SAFE Matched cleanly.
C1700_StrucConcrete!R7 C1700_StrucConcrete 1 In situ concrete, ST1 in blinding 75mm or less in thickness 5 m3 5 m3 — EXACT_SAFE Matched cleanly.
C1700_StrucConcrete!R9 C1700_StrucConcrete 2 In situ concrete, PAV1 concrete slab in apron/toe protection with stone pitching as per Dwg No CP87499/DD/0500 2 m3 2 m3 — EXACT_SAFE Matched cleanly.
C1700_StrucConcrete!R11 C1700_StrucConcrete 3 In situ concrete, RC32/40, 200mm thick in surround detail as per Dwg No CP87499/DD/0500/006 1 m3 1 m3 — EXACT_SAFE Matched cleanly.
C1700_StrucConcrete!R13 C1700_StrucConcrete 4 In situ concrete, RC40/50, in joint as per Dwg No CP87499/DD/0500/006 1 m3 1 m3 — EXACT_SAFE Matched cleanly.
C1700_StrucConcrete!R17 C1700_StrucConcrete 5 Formwork Class F2 300mm wide or less at any inclination 4 m2 4 m2 — EXACT_SAFE Matched cleanly.
C1700_StrucConcrete!R21 C1700_StrucConcrete 6 Bar reinforcement, nominal size 16 millimetres and under Grade 500C to BS 4449 bars in bent and cut lengths no 0.071 tonne 0.071 tonne — EXACT_SAFE Matched cleanly.
C1700_StrucConcrete!R23 C1700_StrucConcrete 7 Fabric reinforcement, A393 to BS 4483 for concrete surround as per in situ joint detail in Dwg No CP87499/DD/0 20 m2 20 m2 — EXACT_SAFE Matched cleanly.
C2400_Blockwork!R7 C2400_Blockwork 1 Repairs to wall of culvert using random rubble blockwork in cement lime mortar designation (iii) in walls to e 1 m3 1 m3 — EXACT_SAFE Matched cleanly.
C2500_SpecialStructures!R6 C2500_SpecialStructures 1 Precast box culvert unit 2m in length with spigot and socket ends as per Dwg Nos CP87499/DD/0500/005 & CP87499 7 no 7 no — EXACT_SAFE Matched cleanly.
C2500_SpecialStructures!R8 C2500_SpecialStructures 2 Precast box culvert unit 2m in length with spigot end and projecting bars per Dwg Nos CP87499/DD/0500/005 & CP 1 no 1 no — EXACT_SAFE Matched cleanly.
C2500_SpecialStructures!R10 C2500_SpecialStructures 3 Precast Concrete Headwall (in 2 sections) as per HW02 detail in Dwg Nos CP87499/DD/0500/005 & CP87499/DD/0500/ 1 no 1 no — EXACT_SAFE Matched cleanly.
C2500_SpecialStructures!R14 C2500_SpecialStructures 4 Handrail for Headwall Detail HW02 1 no 1 no — EXACT_SAFE Matched cleanly.