B500_Drainage!Row 28: description updated from 'Adjustment on last item for variation greater than 150mm above or belo' to 'Adjustment on last item for variation greater than 150mm above or belo'.
Action: Review and confirm Rate Only pricing under updated specification.
B500_Drainage!Row 40: description updated from 'Adjustment on last item for variation greater than 150mm above or belo' to 'Adjustment on last item for variation greater than 150mm above or belo'.
Action: Review and confirm Rate Only pricing under updated specification.
B500_Drainage!Row 44: description updated from 'Adjustment on last item for variation greater than 150mm above or belo' to 'Adjustment on last item for variation greater than 150mm above or belo'.
Action: Review and confirm Rate Only pricing under updated specification.
Original item #7 was split into #7, #7A at B700_Pavements!Row 20 (1349 m2). Confirm distinct rate for each grade.
Action: Confirm independent unit rate for each split item grade.
Original item #7 was split into #7, #7A at B700_Pavements!Row 22 (2164 m2). Confirm distinct rate for each grade.
Action: Confirm independent unit rate for each split item grade.
Prior workbook had 'Discount offered through Aberdeen City Council Supplier Incentive Scheme | %' (editable=True); removed in latest revision.
Action: Do not include withdrawn discount/incentive form or adjustment in final bid.
All subtotal/total cells are static values or blank; verify manual arithmetic against independent Decimal totals.
Action: Cross-check every manually entered subtotal against the Audit Totals table.
| Sheet | Group | Active Items | Priced | Independent Total | Reported Total | Status |
|---|---|---|---|---|---|---|
| A100_Prelims | A100_Prelims | 2 | 0 / 2 | £0.00 | — | INCOMPLETE |
| B200_SiteClearance | B200_SiteClearance | 21 | 0 / 21 | £0.00 | — | INCOMPLETE |
| B300_Fencing | B300_Fencing | 8 | 0 / 8 | £0.00 | — | INCOMPLETE |
| B500_Drainage | B500_Drainage | 27 | 0 / 27 | £0.00 | — | INCOMPLETE |
| B600_Earthworks | B600_Earthworks | 27 | 0 / 27 | £0.00 | — | INCOMPLETE |
| B700_Pavements | B700_Pavements | 11 | 0 / 11 | £0.00 | — | INCOMPLETE |
| B1100_Kerbs-Footways | B1100_Kerbs-Footways | 4 | 0 / 4 | £0.00 | — | INCOMPLETE |
| B1200_TrafficSigns-RoadMarkings | B1200_TrafficSigns-RoadMarkings | 22 | 0 / 22 | £0.00 | — | INCOMPLETE |
| B1400_Electrical | B1400_Electrical | 6 | 0 / 6 | £0.00 | — | INCOMPLETE |
| B2700_AccommWorks | B2700_AccommWorks | 4 | 0 / 4 | £0.00 | — | INCOMPLETE |
| B3000_Landscape | B3000_Landscape | 12 | 0 / 12 | £0.00 | — | INCOMPLETE |
| C200_SiteClearance | C200_SiteClearance | 2 | 0 / 2 | £0.00 | — | INCOMPLETE |
| C600_Earthworks | C600_Earthworks | 14 | 0 / 14 | £0.00 | — | INCOMPLETE |
| C1700_StrucConcrete | C1700_StrucConcrete | 7 | 0 / 7 | £0.00 | — | INCOMPLETE |
| C2400_Blockwork | C2400_Blockwork | 1 | 0 / 1 | £0.00 | — | INCOMPLETE |
| C2500_SpecialStructures | C2500_SpecialStructures | 4 | 0 / 4 | £0.00 | — | INCOMPLETE |
| Cell | Group | Item# | Description | Latest Qty/Unit | Prior Qty/Unit | Contractor Rate | Status | Audit Note |
|---|---|---|---|---|---|---|---|---|
| A100_Prelims!R26 | A100_Prelims | 10 | Survey Engineer for the Overseeing Organisation | 20 op.day | 20 op.day | — | EXACT_SAFE | Matched cleanly. |
| A100_Prelims!R30 | A100_Prelims | 11 | Information board as detailed in Appendix 1/21 | 3 no | 3 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R6 | B200_SiteClearance | 1 | General Site Clearance Area 1 | 0.262 Ha | 0.262 Ha | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R8 | B200_SiteClearance | 2 | General Site Clearance Area 2 | 0.984 Ha | 0.984 Ha | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R10 | B200_SiteClearance | 3 | General Site Clearance Area 3 | 0.263 Ha | 0.263 Ha | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R14 | B200_SiteClearance | 4 | Take up or down and remove to tip off site stonework (in walls) | 627 m3 | 627 m3 | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R16 | B200_SiteClearance | 5 | Take up or down and remove to tip off site post and barbed wire fencing | 356 m | 356 m | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R18 | B200_SiteClearance | 6 | Take up or down and remove to tip off site wooden fencing | 8 m | 8 m | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R20 | B200_SiteClearance | 7 | Take up or down and remove to tip off site traffic sign post | 5 no | 5 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R22 | B200_SiteClearance | 8 | Take up or down and remove to tip off site traffic lit sign post | 5 no | 5 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R24 | B200_SiteClearance | 9 | Take up or down and remove to tip off site half post and chevron marker | 8 no | 8 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R26 | B200_SiteClearance | 10 | Take up or down and set aside for reuse traffic sign face not exceeding 0.50 square metres (Direction Sign) | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R28 | B200_SiteClearance | 11 | Take up or down and set aside for reuse traffic sign and supplementary plate sign face not exceeding 0.50 squa | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R30 | B200_SiteClearance | 12 | Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( | 5 no | 5 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R32 | B200_SiteClearance | 13 | Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R34 | B200_SiteClearance | 14 | Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R36 | B200_SiteClearance | 15 | Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R38 | B200_SiteClearance | 16 | Take up or down and set aside for reuse speed restriction traffic sign face not exceeding 0.50 square metres ( | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R40 | B200_SiteClearance | 17 | Take up or down and set aside for reuse traffic sign face not exceeding 0.50 square metres (Give Way Sign) | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R49 | B200_SiteClearance | 18 | Take up or down and remove to tip off site bollard | 4 no | 4 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R51 | B200_SiteClearance | 19 | Take up or down and remove to tip off site gully grating and frame | 6 no | 6 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R53 | B200_SiteClearance | 20 | Take up or down and set aside for reuse steel farm gates | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B200_SiteClearance!R55 | B200_SiteClearance | 21 | Take up or down and set aside for reuse timber posts for the farm gates | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R6 | B300_Fencing | 1 | Wooden post and 6 wire (barbed) fence 1.15m high as per ACC Standard Detail H77 | 237 m | 237 m | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R8 | B300_Fencing | 2 | Straining posts as per Standard Detail H7 | 4 no | 4 no | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R10 | B300_Fencing | 3 | Concrete foundation to straining posts | 4 no | 4 no | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R14 | B300_Fencing | 4 | Remove from store and re-erect steel field gate 5m wide x 1m high | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R16 | B300_Fencing | 5 | Remove from store and re-erect timber posts 1.8m in length | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R18 | B300_Fencing | 6 | Concrete foundation to timber posts for farm gate | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R22 | B300_Fencing | 7 | Excavation in Hard Material | 1 m3 | 1 m3 | — | EXACT_SAFE | Matched cleanly. |
| B300_Fencing!R26 | B300_Fencing | 8 | Handrail for Headwall Detail HW01 | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R6 | B500_Drainage | 1 | 150mm internal diameter drain specified design Group 1 inside slopes of cuttings or side slopes of embankments | 53 m | 53 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R8 | B500_Drainage | 2 | Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R10 | B500_Drainage | 3 | 150mm internal diameter drain specified design Group 5 in trench depth to invert not exceeding 2 metres, avera | 51 m | 51 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R12 | B500_Drainage | 4 | Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R14 | B500_Drainage | 5 | 225mm internal diameter drain specified design Group 5 in trench depth to invert not exceeding 2 metres, avera | 37 m | 37 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R16 | B500_Drainage | 6 | Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R18 | B500_Drainage | 7 | 300mm internal diameter drain specified design Group 1 in trench depth to invert not exceeding 2 metres, avera | 8 m | 8 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R20 | B500_Drainage | 8 | Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R22 | B500_Drainage | 9 | 300mm internal diameter drain specified design Group 5 in trench depth to invert not exceeding 2 metres, avera | 14 m | 14 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R24 | B500_Drainage | 10 | Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R26 | B500_Drainage | 11 | 150mm internal diameter drain on bed Type Z in trench depth to invert not exceeding 2 metres, average depth to | 9 m | 9 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R28 | B500_Drainage | 12 | Adjustment on last item for variation greater than 150mm above or below average depth of 1.0 metres per 25mm o | m | m | — | RATE_ONLY_REVIEW | Rate-Only specification changed (reference depth 1.2m → 1.0m). |
| B500_Drainage!R38 | B500_Drainage | 13 | One number 100mm internal diameter corrugated purple uPVC with smooth inner surface service duct on bed Type T | 375 m | 375 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R40 | B500_Drainage | 14 | Adjustment on last item for variation greater than 150mm above or below the average depth of 0.45 metres per 2 | m | m | — | RATE_ONLY_REVIEW | Rate-Only specification changed (reference depth 0.85m → 0.45m). |
| B500_Drainage!R42 | B500_Drainage | 15 | Two number 100mm internal diameter corrugated purple uPVC with smooth inner surface service duct on bed Type T | 44 m | 44 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R44 | B500_Drainage | 16 | Adjustment on last item for variation greater than 150mm above or below the average depth of 0.85 metres per 2 | m | m | — | RATE_ONLY_REVIEW | Rate-Only specification changed (reference depth 0.45m → 0.85m). |
| B500_Drainage!R48 | B500_Drainage | 17 | One number 100mm internal diameter black uPVC service duct on bed Type T in trench depth to invert not exceedi | 22 m | 22 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R50 | B500_Drainage | 18 | Adjustment on last item for variation greater than 150mm above or below the average depth of 0.75 metres per 2 | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R52 | B500_Drainage | 19 | One number 100mm internal diameter black uPVC service duct on bed Type T in trench depth to invert not exceedi | 130 m | 130 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R54 | B500_Drainage | 20 | Adjustment on last item for variation greater than 150mm above or below the average depth of 0.55 metres per 2 | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R58 | B500_Drainage | 21 | Drain or Service Protection | 12 m | 12 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R62 | B500_Drainage | 22 | 150mm internal diameter filter drain in trench specified design Group 2 depth to invert not exceeding 2 metres | 411 m | 411 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R72 | B500_Drainage | 23 | Adjustment on last item for variation greater than 150mm above or below average depth of 1.2 metres per 25mm o | m | m | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B500_Drainage!R74 | B500_Drainage | 24 | Type B filter material contiguous with filter drain | 73 m3 | 73 m3 | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R78 | B500_Drainage | 25 | Narrow filter drain Type 9 depth not exceeding 1.5 metres | 37 m | 37 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R82 | B500_Drainage | 26 | Connection of 150mm diameter pipe to existing 150mm diameter drain or existing piped culvert depth to invert n | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R86 | B500_Drainage | 27 | Trapped gully specified design group Type G1 with D400 grating and frame | 7 no | 7 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R88 | B500_Drainage | 28 | Precast concrete chamber Type 7 (1050) Catchpit with D400 cover and frame depth to invert exceeding 1 metres b | 15 no | 15 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R90 | B500_Drainage | 29 | Sectional uPVC footway chamber 450 x 450mm for Street Lighting with cover and frame, depth to uppermost surfac | 6 no | 6 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R92 | B500_Drainage | 30 | 150mm diameter rodding eye (as per SD F84) | 5 no | 5 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R96 | B500_Drainage | 31 | Headwall (precast concrete) type HW01, pipe exceeding 100mm but not exceeding 300mm internal diameter as per D | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R100 | B500_Drainage | 32 | Excavation of soft spots and other voids in the bottom of trenches, chambers and gullies | 5 m3 | 5 m3 | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R102 | B500_Drainage | 33 | Filling of soft spots and other voids in the bottom of trenches, chambers and gullies | 5 m3 | 5 m3 | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R106 | B500_Drainage | 34 | Extra over excavation for excavation in Hard Material in drainage | 20 m3 | 20 m3 | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R108 | B500_Drainage | 35 | Cleaning filter drainage system from CP01 | 220 m | 220 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R110 | B500_Drainage | 36 | Cleaning piped drainage system at connection of Catch Pit CP12 to outfall at Burn of Mundurno | 10 m | 10 m | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R120 | B500_Drainage | 37 | Cleaning of gullies on existing piped drainage system | 4 no | 4 no | — | EXACT_SAFE | Matched cleanly. |
| B500_Drainage!R124 | B500_Drainage | 38 | Infiltration trench 150 dia drain depth to invert not exceeding 2 metres | 36 m | 36 m | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R6 | B600_Earthworks | 1 | Excavation of acceptable material Class 5A (topsoil) | 2347 m3 | 2347 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R8 | B600_Earthworks | 2 | Excavation of acceptable material excluding Class 5A in cutting and other excavation | 809 m3 | 809 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R10 | B600_Earthworks | 3 | Excavation of acceptable material excluding Class 5A in intercepting ditches | 400 m3 | 400 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R12 | B600_Earthworks | 4 | Excavation of unacceptable material Class U1A in cutting or other excavation | 3299 m3 | 3299 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R16 | B600_Earthworks | 5 | Extra over excavation for excavation in Hard Material in cutting or other excavation | 583 m3 | 583 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R18 | B600_Earthworks | 6 | Extra over excavation for excavation in Hard Material in intercepting ditches | 5 m3 | 5 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R20 | B600_Earthworks | 7 | Processing of unacceptable material Class U1A into acceptable material (PROVISIONAL) | m3 | m3 | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B600_Earthworks!R24 | B600_Earthworks | 8 | Deposition of acceptable material in embankments and other areas of fill | 1209 m3 | 1209 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R26 | B600_Earthworks | 9 | Deposition of acceptable material in fill on sub-base material, base and capping | 14 m3 | 14 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R30 | B600_Earthworks | 10 | Disposal of unacceptable material Class U1A | 3299 m3 | 3299 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R32 | B600_Earthworks | 11 | Disposal of acceptable material Class 5A | 1000 m3 | 1000 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R36 | B600_Earthworks | 12 | Imported acceptable material in embankments and other area of fill | 7781 m3 | 7781 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R38 | B600_Earthworks | 13 | Imported acceptable material in embankments and other areas of fill (intercepting ditches) as per Drawing No C | 26 m3 | 26 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R42 | B600_Earthworks | 14 | Compaction of acceptable material in embankments and other areas of fill | 8990 m3 | 8990 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R44 | B600_Earthworks | 15 | Compaction of acceptable material in fill on sub-base material, base and capping | 14 m3 | 14 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R48 | B600_Earthworks | 16 | Geotextile in carriageway (PROVISIONAL) | 3956 m2 | 3956 m2 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R52 | B600_Earthworks | 17 | Excavation of soft spots and other voids below cuttings or under embankments | 20 m3 | 20 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R54 | B600_Earthworks | 18 | Filling of soft spots and other voids below cuttings or under embankments with acceptable material | 20 m3 | 20 m3 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R64 | B600_Earthworks | 19 | Removal of disused gully internal diameter 0.5m | 4 no | 4 no | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R68 | B600_Earthworks | 20 | Topsoiling 150mm thick to surfaces sloping at 10 degrees or less to the horizontal | 5728 m2 | 5728 m2 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R70 | B600_Earthworks | 21 | Topsoiling 150mm thick to surfaces sloping more than 10 degrees to the horizontal | 2395 m2 | 2395 m2 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R72 | B600_Earthworks | 22 | Topsoiling 250mm thick to surfaces sloping at 10 degrees or less to the horizontal | 120 m2 | 120 m2 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R74 | B600_Earthworks | 23 | Topsoiling 250mm thick to surfaces sloping more than 10 degrees to the horizontal | 472 m2 | 472 m2 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R78 | B600_Earthworks | 24 | Completion of formation on acceptable material | 3956 m2 | 3956 m2 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R82 | B600_Earthworks | 25 | Lining of new intercepting ditches to side slopes | 770 m2 | 770 m2 | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R86 | B600_Earthworks | 26 | Clearing of existing Burn of Mundurno at existing culvert | 45 m | 45 m | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R90 | B600_Earthworks | 27 | Removal of standpipes, depth not exceeding 10 metres | 3 no | 3 no | — | EXACT_SAFE | Matched cleanly. |
| B600_Earthworks!R94 | B600_Earthworks | 28 | Trial pit 0-3 metres in depth | 20 m3 | 20 m3 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R6 | B700_Pavements | 1 | Type 1 unbound mixture sub-base in carriageway, hardshoulder and hardstrip | 1028 m3 | 1028 m3 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R10 | B700_Pavements | 2 | AC32 dense base 40/60 Des, 175mm thick in carriageway, hardshoulder and hardstrip | 3494 m2 | 3494 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R12 | B700_Pavements | 3 | AC20 dense binder course 40/60 Des, 60mm thick in carriageway, hardshoulder and hardstrip | 3430 m2 | 3430 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R14 | B700_Pavements | 4 | AC20 dense binder course 40/60 Des, 75mm thick in carriageway, hardshoulder and hardstrip | 45 m2 | 45 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R16 | B700_Pavements | 5 | AC20 dense binder course 40/60 Des, 90mm thick in carriageway, hardshoulder and hardstrip | 198 m2 | 198 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R18 | B700_Pavements | 6 | Hot rolled asphalt 30/14F surf 40/60 Des, with 14mm aggregate surface course 30mm thick with 14/20mm coated ch | 187 m2 | 187 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R20 | B700_Pavements | 7 | Hot rolled asphalt 30/14F surf 40/60 Des PSV 60, with 14mm aggregate surface course 45mm thick with 14/20mm co | 1349 m2 | 3450 m2 | — | SPLIT_OR_AMBIGUOUS | Split from prior single item; requires rate confirmation. |
| B700_Pavements!R22 | B700_Pavements | 7A | Hot rolled asphalt 30/14F surf 40/60 Des PSV 65, with 14mm aggregate surface course 45mm thick with 14/20mm co | 2164 m2 | — | SPLIT_OR_AMBIGUOUS | Split from prior single item; requires rate confirmation. | |
| B700_Pavements!R26 | B700_Pavements | 8 | Regulating binder course AC20 dense bin 40/60 Des in carriageway, hardshoulder and hardstrip to Clause 907 (PR | m3 | m3 | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B700_Pavements!R30 | B700_Pavements | 9 | Tack Coat | 7256 m2 | 7256 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R34 | B700_Pavements | 10 | Milling pavement not exceeding 60mm deep | 38 m2 | 38 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R36 | B700_Pavements | 11 | Milling pavement exceeding 60mm deep but not exceeding 120mm deep | 15 m2 | 15 m2 | — | EXACT_SAFE | Matched cleanly. |
| B700_Pavements!R40 | B700_Pavements | 12 | Reinstate paved areas with permanent reinstatement as detailed in Appendix 7/2, paragraph 5 of the Specificati | m2 | m2 | — | RATE_ONLY_REVIEW | Rate-Only item (excluded from extended quantity sum). |
| B1100_Kerbs-Footways!R6 | B1100_Kerbs-Footways | 1 | Precast concrete kerb Type K2 laid straight or curved exceeding 12 metres radius | 129 m | 129 m | — | EXACT_SAFE | Matched cleanly. |
| B1100_Kerbs-Footways!R8 | B1100_Kerbs-Footways | 2 | Precast concrete kerb Type K2 laid to curves not exceeding 12 metres radius | 25 m | 25 m | — | EXACT_SAFE | Matched cleanly. |
| B1100_Kerbs-Footways!R10 | B1100_Kerbs-Footways | 3 | Precast concrete kerb Type K6 laid straight or curved exceeding 12 metres radius | 1 m | 1 m | — | EXACT_SAFE | Matched cleanly. |
| B1100_Kerbs-Footways!R12 | B1100_Kerbs-Footways | 4 | Precast concrete kerb Type K7 laid straight or curved exceeding 12 metres radius | 1 m | 1 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R6 | B1200_TrafficSigns-RoadMarkings | 1 | Permanent retroreflective traffic sign to Diagram 670 (40mph) as Lit Sign Unit sign face exceeding 0.25 square | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R8 | B1200_TrafficSigns-RoadMarkings | 2 | Temporary retroreflective traffic sign to Diagram 7014 (New Road Layout Ahead) as non-Lit Sign Unit sign face | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R10 | B1200_TrafficSigns-RoadMarkings | 3 | Temporary retroreflective traffic sign to Diagram 7014 (New Road Layout Ahead) as non-Lit Sign Unit sign face | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R12 | B1200_TrafficSigns-RoadMarkings | 4 | Remove from store and re-erect retroreflective traffic sign to Diagram 671 (National Speed Limit @750mm Ø) as | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R14 | B1200_TrafficSigns-RoadMarkings | 5 | Remove from store and re-erect retroreflective traffic sign to Diagram 670 (40mph @750mm Ø) as lit Sign Unit s | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R16 | B1200_TrafficSigns-RoadMarkings | 6 | Remove from store and re-erect retroreflective traffic signs back to back to Diagram 670 (40mph & 30mph @600mm | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R18 | B1200_TrafficSigns-RoadMarkings | 7 | Remove from store and re-erect retroreflective traffic signs to Diagram 512.1 and supplementary plate to Diag | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R20 | B1200_TrafficSigns-RoadMarkings | 8 | Remove from store and re-erect retroreflective traffic sign to Diagram 602 (Give way) as non lit Sign Unit sig | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R22 | B1200_TrafficSigns-RoadMarkings | 9 | Remove from store and re-erect retroreflective traffic sign x 2no back to back (Direction Sign) as non lit Sig | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R32 | B1200_TrafficSigns-RoadMarkings | 10 | Remove from store and re-erect retroreflective traffic signs back to back to Diagram 670 & Diagram 671 (40mph | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R36 | B1200_TrafficSigns-RoadMarkings | 11 | Continuous line in white thermoplastic screed with applied solid glass beads 0.150 metres wide (Diag 1012.1 Ha | 791 m | 791 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R38 | B1200_TrafficSigns-RoadMarkings | 12 | Intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with 4 metre li | 262 m | 262 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R40 | B1200_TrafficSigns-RoadMarkings | 13 | Intermittent line in white thermoplastic screed with applied solid glass beads 0.2 metres wide with 0.6 metre | 18 m | 18 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R42 | B1200_TrafficSigns-RoadMarkings | 14 | Intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with 0.6 metre | 7 m | 7 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R44 | B1200_TrafficSigns-RoadMarkings | 15 | Intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with 1 metre li | 39 m | 39 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R46 | B1200_TrafficSigns-RoadMarkings | 16 | Ancillary line in white thermoplastic screed with applied solid glass beads 0.15 metres wide in hatched areas | 5 m | 5 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R48 | B1200_TrafficSigns-RoadMarkings | 17 | Triangle in white thermoplastic screed with applied solid glass beads to (Diag 1023A) | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R50 | B1200_TrafficSigns-RoadMarkings | 18 | Letters in white thermoplastic screed with applied solid glass beads 1.6 metres high (Diag 1024 Slow) | 16 no | 16 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R52 | B1200_TrafficSigns-RoadMarkings | 19 | Removal of continuous line in white thermoplastic screed with applied solid glass beads 0.150 metres wide (Dia | 10 m | 10 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R54 | B1200_TrafficSigns-RoadMarkings | 20 | Removal of intermittent line in white thermoplastic screed with applied solid glass beads 0.1 metres wide with | 12 m | 12 m | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R64 | B1200_TrafficSigns-RoadMarkings | 21 | Removal of letters in white thermoplastic screed with applied solid glass beads 1.6 metres high (Diag 1024 Slo | 4 no | 4 no | — | EXACT_SAFE | Matched cleanly. |
| B1200_TrafficSigns-RoadMarkings!R68 | B1200_TrafficSigns-RoadMarkings | 22 | Permanent bollard retro-reflective, Weebol style with blank aspect within NAL 50 x 50mm retention socket | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B1400_Electrical!R7 | B1400_Electrical | 1 | 2.5mm2 3 Core XLPE/SWA/PVC cable with copper conductors | 148 m | 148 m | — | EXACT_SAFE | Matched cleanly. |
| B1400_Electrical!R13 | B1400_Electrical | 3 | Single way cut out termination to 3 core PVC/SWA/PVC cable in road lighting column or feeder pillar | 12 no | 12 no | — | EXACT_SAFE | Matched cleanly. |
| B1400_Electrical!R15 | B1400_Electrical | 4 | Two way cut out termination to 3 core PVC/SWA/PVC cable in road lighting column | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B1400_Electrical!R17 | B1400_Electrical | 5 | Supply and install cut out unit in sign lighting column | 7 no | 7 no | — | EXACT_SAFE | Matched cleanly. |
| B1400_Electrical!R19 | B1400_Electrical | 6 | Supply and install cut out unit in lighting column no. 44 Denmore Road | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| B1400_Electrical!R23 | B1400_Electrical | 7 | Supply and install earth pit and rod sign pole | 3 no | 3 no | — | EXACT_SAFE | Matched cleanly. |
| B2700_AccommWorks!R7 | B2700_AccommWorks | 1 | Trench for Openreach BT duct exceeding 300 mm but not exceeding 450 mm wide depth not exceeding 1.5m in carria | 6 m | 6 m | — | EXACT_SAFE | Matched cleanly. |
| B2700_AccommWorks!R9 | B2700_AccommWorks | 2 | Trench for Openreach BT duct exceeding 300 mm but not exceeding 450 mm wide depth not exceeding 1.5m in verges | 295 m | 295 m | — | EXACT_SAFE | Matched cleanly. |
| B2700_AccommWorks!R13 | B2700_AccommWorks | 3 | Excavation of Joint hole depth not exceeding 1.5m in verges to locate SSE Distribution cables | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B2700_AccommWorks!R15 | B2700_AccommWorks | 4 | Excavation of Joint hole depth not exceeding 1.5m in carriageways, footways and paved areas to locate SSE Dist | 2 no | 2 no | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R6 | B3000_Landscape | 1 | Vegetation clearance to surfaces sloping at 10 degrees or less to the horizontal | 5848 m2 | 5848 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R8 | B3000_Landscape | 2 | Vegetation clearance to surfaces sloping at more than 10 degrees to the horizontal | 2867 m2 | 2867 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R10 | B3000_Landscape | 3 | Final preparation of surfaces sloping at 10 degrees or less to the horizontal | 5848 m2 | 5848 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R12 | B3000_Landscape | 4 | Final preparation of surfaces sloping at more than 10 degrees to the horizontal | 2867 m2 | 2867 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R14 | B3000_Landscape | 5 | Final cultivations to surfaces sloping at 10 degrees or less to the horizontal | 5848 m2 | 5848 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R16 | B3000_Landscape | 6 | Final cultivations to surfaces sloping at more than 10 degrees to the horizontal | 2867 m2 | 2867 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R20 | B3000_Landscape | 7 | Grass seeding to Amenity Grassland areas at 35g/sqm by conventional sowing to surfaces sloping at 10 degrees o | 2680 m2 | 2680 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R22 | B3000_Landscape | 8 | Grass seeding to Amenity Grassland area at 35g/sqm by conventional sowing areas to surfaces sloping at more th | 734 m2 | 734 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R24 | B3000_Landscape | 9 | Grass seeding to Species Rich Grassland at 3g/sqm by conventional sowing to surfaces sloping at 10 degrees or | 114 m2 | 114 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R26 | B3000_Landscape | 10 | Grass seeding to Species Rich Grassland at 3g/sqm by conventional sowing to surfaces sloping at more than 10 d | 452 m2 | 452 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R28 | B3000_Landscape | 11 | Grass seeding to Meadow Mix at 3g/sqm by conventional sowing to surfaces sloping at 10 degrees or less to the | 2830 m2 | 2830 m2 | — | EXACT_SAFE | Matched cleanly. |
| B3000_Landscape!R30 | B3000_Landscape | 12 | Grass seeding to Meadow Mix at 3g/sqm by conventional sowing to surfaces sloping at more than 10 degrees to th | 1582 m2 | 1582 m2 | — | EXACT_SAFE | Matched cleanly. |
| C200_SiteClearance!R6 | C200_SiteClearance | 1 | Partial demolition of of existing culvert - 750mm diameter precast concrete pipe | 5 m | 5 m | — | EXACT_SAFE | Matched cleanly. |
| C200_SiteClearance!R8 | C200_SiteClearance | 2 | Partial demolition of existing culvert - stone culvert comprising random rubble wall, granite roof slabs and c | 4 m | 4 m | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R6 | C600_Earthworks | 1 | Excavation of acceptable material Class 5A (topsoil) in culvert | 40 m3 | 40 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R8 | C600_Earthworks | 2 | Excavation of acceptable material excluding Class 5A in culvert | 60 m3 | 60 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R10 | C600_Earthworks | 3 | Excavation of unacceptable material Class U1A in culvert | 60 m3 | 60 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R14 | C600_Earthworks | 4 | Extra over excavation for excavation in Hard Material in culvert | 3 m3 | 3 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R18 | C600_Earthworks | 5 | Deposition of acceptable material in embankments and other areas of fill | 40 m3 | 40 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R20 | C600_Earthworks | 6 | Deposition of acceptable material Class 5A in embankments and other areas of fill | 20 m3 | 20 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R23 | C600_Earthworks | 7 | Disposal of unacceptable material Class U1A | 60 m3 | 60 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R27 | C600_Earthworks | 8 | Imported acceptable material Class 1A in base of culvert | 8 m3 | 8 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R29 | C600_Earthworks | 9 | Imported acceptable well graded course granular material suitable for use in a watercourse as bedding in culve | 5 m3 | 5 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R33 | C600_Earthworks | 10 | Compaction of acceptable material Class 1A in base of culvert | 8 m3 | 8 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R35 | C600_Earthworks | 11 | Compaction of acceptable material in embankments and other areas of fill | 60 m3 | 60 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R39 | C600_Earthworks | 12 | Geotextile membrane in culvert | 24 m2 | 24 m2 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R43 | C600_Earthworks | 13 | Excavation of soft spots and other voids below cuttings or under embankments | 2 m3 | 2 m3 | — | EXACT_SAFE | Matched cleanly. |
| C600_Earthworks!R45 | C600_Earthworks | 14 | Filling of soft spots and other voids below cuttings or under embankments with acceptable material | 2 m3 | 2 m3 | — | EXACT_SAFE | Matched cleanly. |
| C1700_StrucConcrete!R7 | C1700_StrucConcrete | 1 | In situ concrete, ST1 in blinding 75mm or less in thickness | 5 m3 | 5 m3 | — | EXACT_SAFE | Matched cleanly. |
| C1700_StrucConcrete!R9 | C1700_StrucConcrete | 2 | In situ concrete, PAV1 concrete slab in apron/toe protection with stone pitching as per Dwg No CP87499/DD/0500 | 2 m3 | 2 m3 | — | EXACT_SAFE | Matched cleanly. |
| C1700_StrucConcrete!R11 | C1700_StrucConcrete | 3 | In situ concrete, RC32/40, 200mm thick in surround detail as per Dwg No CP87499/DD/0500/006 | 1 m3 | 1 m3 | — | EXACT_SAFE | Matched cleanly. |
| C1700_StrucConcrete!R13 | C1700_StrucConcrete | 4 | In situ concrete, RC40/50, in joint as per Dwg No CP87499/DD/0500/006 | 1 m3 | 1 m3 | — | EXACT_SAFE | Matched cleanly. |
| C1700_StrucConcrete!R17 | C1700_StrucConcrete | 5 | Formwork Class F2 300mm wide or less at any inclination | 4 m2 | 4 m2 | — | EXACT_SAFE | Matched cleanly. |
| C1700_StrucConcrete!R21 | C1700_StrucConcrete | 6 | Bar reinforcement, nominal size 16 millimetres and under Grade 500C to BS 4449 bars in bent and cut lengths no | 0.071 tonne | 0.071 tonne | — | EXACT_SAFE | Matched cleanly. |
| C1700_StrucConcrete!R23 | C1700_StrucConcrete | 7 | Fabric reinforcement, A393 to BS 4483 for concrete surround as per in situ joint detail in Dwg No CP87499/DD/0 | 20 m2 | 20 m2 | — | EXACT_SAFE | Matched cleanly. |
| C2400_Blockwork!R7 | C2400_Blockwork | 1 | Repairs to wall of culvert using random rubble blockwork in cement lime mortar designation (iii) in walls to e | 1 m3 | 1 m3 | — | EXACT_SAFE | Matched cleanly. |
| C2500_SpecialStructures!R6 | C2500_SpecialStructures | 1 | Precast box culvert unit 2m in length with spigot and socket ends as per Dwg Nos CP87499/DD/0500/005 & CP87499 | 7 no | 7 no | — | EXACT_SAFE | Matched cleanly. |
| C2500_SpecialStructures!R8 | C2500_SpecialStructures | 2 | Precast box culvert unit 2m in length with spigot end and projecting bars per Dwg Nos CP87499/DD/0500/005 & CP | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| C2500_SpecialStructures!R10 | C2500_SpecialStructures | 3 | Precast Concrete Headwall (in 2 sections) as per HW02 detail in Dwg Nos CP87499/DD/0500/005 & CP87499/DD/0500/ | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |
| C2500_SpecialStructures!R14 | C2500_SpecialStructures | 4 | Handrail for Headwall Detail HW02 | 1 no | 1 no | — | EXACT_SAFE | Matched cleanly. |